April 19, 2023

GE window air conditioner error codes

GE

These error code explanations can help you diagnose a problem with your GE window air conditioner. For repair how-to help, visit the PartsDirect repair help section, which includes repair help for window air conditioners, major appliances, lawn and garden equipment, garage door openers, vacuum cleaners and more. Search for your model number to find a complete list of replacement parts for your window air conditioner.

Error Code
Condition
DIY advice
E1

Electronic control board function error

Check/Repair

Unplug the window air conditioner for 1 minute and then plug it back in to reset the electronic control board. If the code doesn't clear, unplug the window air conditioner and check the wire harness connections on the electronic control board. Check the electronic control board for visible damage such as a burn mark. Replace the electronic control board if it's damaged or defective.

Possible parts
Electronic control board, Wire harness
E4 (Portable A/Cs only)

Water bucket is full or defective bucket float switch

Check/Repair

If the collection bucket is full, empty the bucket. If the bucket isn't full, unplug the air conditioner and check the wire harness connections on the electronic control board. Check for a pinched or damaged wire in the wire harness between the electronic control board and the collection bucket float switch. Check the float switch for damage. If the float switch is defective, replace it.

Possible parts
Float switch, Wire harness, Electronic control board

Most common symptoms to help you fix your air compressors

Choose a symptom to see related air compressor repairs.

Main causes: lack of electrical power, check valve failure, bad pressure switch…

Main causes: tank drain valve open or leaking air, leaky air tank, bad safety valve, worn pump seals, bad pump valve pla…

Main causes: bad safety valve, pressure switch failure…

Main cause: faulty output air pressure regulator…

Main causes: rusted air tank, loose air tube fitting connections, bad check valve, leaky safety valve, bad tank drain va…

Main cause: bad air tank pressure gauge…

Main causes: loose air tube fitting connections, bad check valve, faulty safety valve, damaged or corroded air tank, bad…

Most common repair guides to help fix your air compressors

These step-by-step repair guides will help you safely fix what’s broken on your air compressor.

How to replace an air compressor pressure switch

How to replace an air compressor pressure switch

You can replace a broken air compressor pressure switch in about 45 minutes. …

Repair difficulty
Time required
 45 minutes or less
How to rebuild an air compressor pump

How to rebuild an air compressor pump

If the air compressor won't fill the tank with compressed air, rebuild the pump using these steps in about 45 minutes. …

Repair difficulty
Time required
 45 minutes or less
How to replace an air compressor check valve

How to replace an air compressor check valve

You can replace a defective air compressor check valve in about 10 minutes.…

Repair difficulty
Time required
 15 minutes or less

Effective articles & videos to help repair your air compressors

Use the advice and tips in these articles and videos to get the most out of your air compressor.

How to tell if a fuse is blown

How to tell if a fuse is blown

Learn how to tell whether a fuse is blown…

How to reduce air compressor noise

How to reduce air compressor noise

Find out how to reduce air compressor noise.…

How to maintain an oil-lubricated air compressor

How to maintain an oil-lubricated air compressor

See how to perform routine maintenance on your oil-lubricated air compressor.…